Background

Since the outbreak of the COVID-19 pandemic at the end of 2019, nucleic acid testing for the virus has never stopped. Nucleic acid testing has become the most important detection method during the pandemic. PCR is short for Polymerase Chain Reaction, a detection method that amplifies genes so that trace amounts of genetic material can be increased to the detectable level. PCR laboratories, also known as gene amplification laboratories, undertake the function of detecting viruses in clinical patients, which plays a critical role especially during the pandemic.

A PCR laboratory is typically divided into four areas: reagent preparation area, specimen preparation area, gene amplification area, and product analysis area. Each area has a dedicated buffer area and a separate clean corridor. PCR laboratories have strict requirements for air conditioning and ventilation systems.


SINO KING Solution for PCR Laboratory Air Conditioning Systems

To meet the specific needs of PCR laboratory air conditioning systems, SINO KING recommends using a packaged purification direct-expansion air conditioning unit for PCR laboratories. The unit features a fresh air system design with built-in cooling and heating sources, and includes sections for air intake, primary filter, air supply fan, airflow equalization, medium efficiency filter, direct expansion, electric reheat, humidification, and air discharge. The unit offers differentiated configurations to meet the actual needs of different projects. Depending on the configuration, the outdoor unit may be equipped with a DC variable frequency scroll compressor or a fixed frequency scroll compressor, and the indoor unit may have either a horizontal or a vertical structure.

Standard Configuration 1:

①Indoor Unit: Aluminum alloy frame with foam panel structure, robust structure with excellent thermal insulation, air leakage rate below 0.03%, equipped with functional sections: air intake section (damper + optional air outlet electric preheating), primary filter, airflow equalization, supply fan (variable frequency volute-free fan), medium efficiency filter, direct expansion, electric reheat, humidification, and air discharge.

②Outdoor unit: DC variable frequency outdoor unit

Standard Configuration 2:

①Indoor unit: Aluminum alloy frame with foam panel structure, robust structure with excellent thermal insulation, air leakage rate below 0.03%, equipped with functional sections: air intake section (damper + optional air outlet electric preheating), primary filter, supply fan (fixed frequency ordinary centrifugal fan), airflow equalization, medium efficiency filter, direct expansion, electric reheat, humidification, and air discharge.

②Outdoor unit: Fixed frequency outdoor unit.



industry case

    1. Chongqing People's Hospital

      Chongqing People's Hospital

    1. Jiading District Central Hospital

      Jiading District Central Hospital

    1. Nanjing Jiangning Hospital of Traditional Chinese Medicine

      Nanjing Jiangning Hospital of Traditional Chinese Medicine

    1. Shanghai Tongji Hospital

      Shanghai Tongji Hospital

    1. Xi'an Honghui Hospital

      Xi'an Honghui Hospital

    1. Yiwu Central Hospital

      Yiwu Central Hospital

    1. The 909th Hospital of the Joint Logistics Support Force of the Chinese People's Liberation Army

      The 909th Hospital of the Joint Logistics Support Force of the Chinese People's Liberation Army